IEEE Standard for Standard for Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
Course Outline
This 5-hour course presents the electrical, mechanical, and safety requirements for liquid-immersed distribution and power transformers, and autotransformers and regulating transformers; single and polyphase, with voltages of 601 V or higher in the highest voltage winding. This standard is a basis for the establishment of performance, limited electrical and mechanical interchangeability, and safety requirements of equipment described; and for assistance in the proper selection of such equipment.
The course materials are based entirely on IEEE C57.12.00-2006, Standard for Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers. It will be necessary for the student to obtain a copy of IEEE C57.12.00-2006. This is a very useful resource and is recommended that all practicing electrical or project engineers involved in the specification, design, installation, and maintenance of liquid-immersed distribution, power, and regulating transformers should be familiar with and up to date with the requirements provided in this standard.
This course includes
a multiple-choice quiz at the end, which is designed to enhance the understanding
of the course materials.
Learning Objective
At the conclusion of this course, the student will be familiar with:
Intended Audience
The intended audience is professional electrical engineers, project managers, and project engineers, involved in the specification, design, installation, and maintenance of liquid-immersed distribution, power, and regulating transformers.
Benefit to Attendees
This standard can establish a basis of performance, limited electrical and mechanical interchangeability, and safety requirements of liquid-immersed distribution, power and regulating transformers; and for assistance in the proper specification and selection of these transformers.
Course Introduction
This 5-hour course presents the electrical, mechanical, and safety requirements for liquid-immersed distribution and power transformers, and autotransformers and regulating transformers; single and polyphase, with voltages of 601 V or higher in the highest voltage winding. This standard is a basis for the establishment of performance, limited electrical and mechanical interchangeability, and safety requirements of equipment described; and for assistance in the proper selection of such equipment.
The course materials are based entirely on IEEE C57.12.00-2006, Standard for Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers. It will be necessary for the student to obtain a copy of IEEE C57.12.00-2006. This is a very useful resource and is recommended that all practicing electrical or project engineers involved in the specification, design, installation, and maintenance of liquid-immersed distribution, power, and regulating transformers should be familiar with and up to date with the requirements provided in this standard.
Course Content
This standard applies to liquid-immersed distribution and power transformers, and autotransformers and regulating transformers; single and polyphase, with voltages of 601 V or higher in the highest voltage winding. You are required to obtain a copy of IEEE C57.12.00-2006, Standard for Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers. The standard is a useful tool that provides the general requirements for liquid-immersed power and distribution transformers that every practicing professional should be familiar with.
IEEE C57.12.00-2006, Standard for Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers can be purchased from the following websites:
http://www.nfpa.com/
http://www.global.ihs.com/
IEEE C57.12.00-2006, Standard for Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
Table of Contents
Chapter 1 - Overview
Chapter 2 – Normative references
Chapter 3 – Definitions
Chapter 4 – Service conditions
Chapter 5 – Rating data
Chapter 6 – Construction
Chapter 7 – Short-circuit characteristics
Chapter 8 – Testing and calculations
Chapter 9 – Tolerances
Chapter 10 – Connection of transformers for shipment
Course Summary
This 5-hour course presents the electrical, mechanical, and safety requirements for liquid-immersed distribution and power transformers, and autotransformers and regulating transformers; single and polyphase, with voltages of 601 V or higher in the highest voltage winding. This standard is a basis for the establishment of performance, limited electrical and mechanical interchangeability, and safety requirements of equipment described; and for assistance in the proper selection of such equipment.
Related Links
For additional technical information related to this subject, please visit the following websites or web pages:
http://www.ansi.com/
http://www.ieee.com/
http://www.nfpa.com
http://www.nema.com
Quiz
Once you finish studying the above course content, you need to take a quiz to obtain the PDH credits.